FREE Shipping available for orders above Rs 15,000*

Troubleshooting. Image. Smudged/Streaked Canon imageCLASS MF3010

Bleeding (smear) occurs immediately after the power is turned on for the first time for the day

Description

There is sometimes a case where the difference of temperature between air and inside of the machine causes moisture to occur on the toner immediately after the power is turned on for the first time for the day.

As a result, when the toner transferred on a sheet at the time of initial printing passes through the fixing assembly, moisture on the toner is vaporized into steam, causing breading (smear) to occur.

Field Remedy

Prevent bleeding using the following user mode items.

Setting itemsSetting valueDescriptionAdditional information
Adjustment/ Maintenance > Special Processing
> Special Mode Z
Not used,Mode 1
through 4 (Factory
setting: Mode 2)
Make a setting to perform thinning of printed image data by processing of the controller. When the value set for the mode increases, the amount of thinning increases. (The image density decreases.)Printing time does not increase because the method of image processing performed by the controller is changed. This mode is less effective than Mode B.
Adjustment/ Maintenance > Special Processing
> Special Mode B
Not used,Mode 1
through 3 (Factory setting: Not used)
Extend the initial rotation period by processing of the engine. When the value
set for the mode increases, the initial rotation period is extended.
The initial rotation period in engine operation is
extended, and printing time increases. The initial rotation period for each mode is shown below. Mode 1: 13
sec, Mode 2: 30 sec, Mode 3:
60 sec

Error Codes List Brother DCP-B7535DW

  • Code: 0102

Description: SIC error or motor driver error occurred.

Remedy:1 Main PCB failure Replace the main PCB ASSY.

  • Code: 0201

Description: Cannot detect the synchronized signal of the paper feed motor. The speed of the paper feed motor does not stabilize within the specified time.

Remedy:

  • Connection failure of the paper feed motor flat cable Reconnect the paper feed motor flat cable.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Paper feed motor flat cable failure Replace the paper feed motor flat cable.
  • Damaged parts in main drive Replace the frame L unit.
  • Damaged fuser unit Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY.
  • Code: 0300

Description: Cannot detect the lock signal of the polygon motor for the laser unit. (second time)

Remedy:

  • Connection failure of the polygon motor harness Reconnect the polygon motor harness.
  • Laser unit failure Replace the laser unit.
  • Main PCB failure Replace the main PCB ASSY.

 

  • Code: 0305

Description: Cannot detect the lock signal of the polygon motor for the laser unit. (first time)

Remedy:

  • Connection failure of the polygon motor harness Reconnect the polygon motor harness.
  • Laser unit failure Replace the laser unit.
  • Main PCB failure Replace the main PCB ASSY.
  • Code: 0401

Description sensor failure (second time)

Remedy:<User Check> • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.

  • Connection failure of the laser unit flat cable Reconnect the laser unit flat cable.
  • Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: 0405

Description sensor failure (first time)

Remedy:<User Check> • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.
1) Connection failure of the laser unit flat cable Reconnect the laser unit flat cable.

  • Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.

 

  • Code: 0501

Description: The centre thermistor of the fuser unit has not reached the specified temperature within the specified time.

Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

  • Connection failure of the centre or side thermistor harness of the fuser unit Reconnect the centre or side thermistor harness of the fuser unit.
  • Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
  • Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Eject sensor PCB failure Replace the eject sensor PCB ASSY.
  • Fuser unit failure Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY.

 

  • Code: 0502

Description: The centre thermistor of the fuser unit has not reached the specified temperature within the specified time after it was heated normally to the certain level.

Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

  • Connection failure of the centre or side thermistor harness of the fuser unit Reconnect the centre or side thermistor harness of the fuser unit.
  • Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
  • Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Eject sensor PCB failure Replace the eject sensor PCB ASSY.
  • Fuser unit failure Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY.
  • Code: 0503

Description: The centre thermistor of the fuser unit detected a temperature higher than the specified value.

Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

  • Connection failure of the centre or side thermistor harness of the fuser unit Reconnect the centre or side thermistor harness of the fuser unit.
  • Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
  • Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Eject sensor PCB failure Replace the eject sensor PCB ASSY.
  • Fuser unit failure Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY.

 

  • Code: 0504

Description: After the heat unit was heated normally, the centre thermistor of the fuser unit detected a temperature lower than the specified value.

Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

  • Connection failure of the centre or side thermistor harness of the fuser unit Reconnect the centre or side thermistor harness of the fuser unit.
  • Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
  • Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Eject sensor PCB failure Replace the eject sensor PCB ASSY.
  • Fuser unit failure Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY.
  • Code: 0505

Description: The centre thermistor of the fuser unit detected a temperature rise greater than the specified value within the specified time.

Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

  • Connection failure of the centre or side thermistor harness of the fuser unit Reconnect the centre or side thermistor harness of the fuser unit.
  • Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
  • Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Eject sensor PCB failure Replace the eject sensor PCB ASSY.
  • Fuser unit failure Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY.

 

  • Code: 0506

Description: The centre thermistor of the fuser unit detected a temperature fall greater than the specified value within the specified time.

Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

  • Connection failure of the centre or side thermistor harness of the fuser unit Reconnect the centre or side thermistor harness of the fuser unit.
  • Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
  • Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
  • Connection failure of the low voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
  • Eject sensor PCB failure Replace the eject sensor PCB ASSY.
  • Fuser unit failure Replace the fuser unit.
  • Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
  • Main PCB failure Replace the main PCB ASSY

 

Used for the following models DCP-B7500D, DCP-B7520DW, DCP-B7530DN, DCP-B7535DW, DCP-L2510D, DCP-L2511D, DCP-L2512D, DCP-L2530DW, DCP-L2531DW, DCP-L2532DW, DCP-L2535D, DCP-L2535DW, DCP-L2536D, DCP-L2537DW, DCP-L2550DN, DCP-L2550DW, DCP-L2551DN, DCP-L2551DW, DCP-L2552DN, DCP7090, DCP7095D, DCP7190DN, DCP7195DW, HL-L2390DW, HL-L2395DW, MFC-B7700D, MFC-B7715DW, MFC-B7720DN, MFC-L2690DW, MFC-L2710DN, MFC-L2710DW, MFC-L2712DN, MFC-L2712DW, MFC-L2713DW, MFC-L2715D, MFC-L2715DW, MFC-L2716D, MFC-L2716DW, MFC-L2717DW, MFC-L2730DW, MFC-L2732DW, MFC-L2750DW, MFC-L2750DWXL, MFC-L2751DW, MFC-L2752DW, MFC-L2770DW, MFC-L2771DW, MFC7390, MFC7490D, MFC7890DN, […]

Back to Top
Product has been added to your cart
WhatsApp chat